In many places from chemistry laboratories to industrial services, to be able to ensure the security of life and property against a possible fireplace hazard, extinguishing systems are used along with detection and alarm systems. It can be extraordinarily important that the extinguishing techniques installed may be triggered by the fire extinguishing control panel, to find a way to eliminate a possible fire with early intervention.
In order to satisfy these wants, and with 35 years of sectoral information and expertise, Mavili Elektronik provides:
Maxlogic Conventional Fire Extinguishing Control Panel working based on the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which permits the remote performance of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing course of to be started manually and remotely; and
to guarantee that the extinguishing course of can be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these units are produced using surface-mount know-how and are geared toward making the automation of the extinguishing system and fire and gasoline detection system perfect.
Image copyright: Mavili
Mavili Elektronik develops its products by all the time contemplating the wants of the set up. In instances that require the combination of the extinguishing system with the clever addressable fire detection system, it offers solutions via the monitoring modules that even have a ‘supervised’ possibility.
Supervised monitoring modules play an important function in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a attainable open or short circuit within the wiring between the contact monitoring modules and the peripheral techniques can cause disruption of the triggering, with doubtlessly crucial consequences. For this cause, when choosing monitoring modules, it must be taken under consideration that they’ve supervised options.
เกจวัดแรงดัน : Mavili
Since Maxlogic clever addressable hearth detection and alarm management panels are continually speaking with ‘supervise’ contact monitoring modules related to cable loops and compliant with EN 54-17 and EN 54-18 standards, it makes it simpler to monitor situations corresponding to open circuits and quick circuits which will occur in the system. Many tasks could be carried out in the fireplace extinguishing installation, such as the control and monitoring of all valves that may interrupt the circulate of water, water move alarm switches, strain change, and electric or diesel hearth pumps.
By adding two contact monitoring modules to 2 separate relay outputs located above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be used to control errors and the opposite to control the fireplace scenario, monitoring and control of the extinguishing system via an intelligent addressable hearth detection and alarm system may be performed effectively.
For extra info, go to www.mavili.com.tr/en